MPA 1/4 & 1/2 Turn Speed Torque Relationship
        

 

MPA00> TTL Control         MPA01> RS485 Serial Control
MPA00 / MPA01   are 1/4 & 1/2 turn models
Time for 1/4 turn Temps par 1/4 rev. Zeit per 1/4 Rev.
Power Supply
Alimentation
Spannung
Torque at end speed
Torque après démarrage
Drehmoment nach Anlauf
Torque at pullout
Torque au démarrage
Drehmoment bei Anlauf
5.0 sec
12 VDC @ 1.0 A
24 in-lbs
2.7 Nm
35 in-lbs
4.0 Nm
3.2 sec
12 VDC @ 0.7 A
16 in-lbs
1.8 Nm
35 in-lbs
4.0 Nm
5.0 sec
16 VDC @ 1.5 A
37 in-lbs
4.2 Nm
43 in-lbs
4.9 Nm
2.5 sec
16 VDC @ 0.8 A
24 in-lbs
2.7 Nm
43 in-lbs
4.9 Nm
3.0 sec
24 VDC @ 1.3 A
34 in-lbs
3.8 Nm
43 in-lbs
4.9 Nm
4.7 sec
12 VAC @ 1.5 A
25 in-lbs
2.8 Nm
25 in-lbs
2.8 Nm
3.2 sec
12 VAC @ 1.2 A
19 in-lbs
2.1 Nm
25 in-lbs
2.8 Nm
5.0 sec
16 VAC @ 2.2 A
37 in-lbs
4.2 Nm
40 in-lbs
4.5 Nm
2.5 sec
16 VAC @ 1.5 A
23 in-lbs
2.6 Nm
40 in-lbs
4.5 Nm
1.7 sec
24 VAC @ 2.1 A
33 in-lbs
3.7 Nm
43 in-lbs
4.9 Nm
15 sec
24 VAC @ 2.1 A
160 in-lbs *
18 Nm *
160 in-lbs *
18 Nm *

 

SELECT any torque of operation (dip switch settings on board) and, depending on your supply voltage, you get the speed as per the table above. For 160 in-lbs * you will need an MPA06, please inquire.

The unit will operate reliably with any supply voltage between 12 and 24 Volts AC or DC